PRODUCTS

TURUNCU PAKET® REINFORCEMENT PLASTERTermal Insulation Reinforcement Plaster

APPLICATION FIELD

Used for coating of polystyrene and STONEWOOL plates.

REQUIREMENTS

  • Applied as a reinforcement plaster on EPS, XPS and STONEWOOL plate.
  • Provides a smooth surface.
  • Exhibits a high adhesion strength on termal insulation board with the polymer additives it contains.

TECHNICAL VALUES

Adhesive Strength, N/mm²

≥ 0,1

Shininess

Matt;  G3

Dry Film Thickness

> 400; E5

Grain Size, μm

< 1500; S3

Water Vapour Transmission Rate, g/(m².day)

15<V2≤150

Water Transmission Rate, kg/(m².hour0.5)

≤ 0,1; W3

Crack Bridging

A0

CO2 Permeability

C0

Resistance To Mould Growth

K2

TS EN 1062-1

G3

E5

S3

V2

W3

A0

C0

K2

 

APPLICATION

PREPARATION of the MORTAR 

  • A proper amount of water shall be put inside the mixing vessel (6-6.75 l water/25 kg bag).
  • Powder material shall be added and stirred with hand mixer at low speed.
  • After resting for 5 minutes, the plaster shall be stirred until achieving a homogeneous mixture.
  • One coat of mortar (3 mm) shall be applied on the plate affixed in advance with a steel trowel.
  • Reinforcement net shall be placed by stretching it and without folding it, and the connection points of the net shall be overlapped.
  • Net shall be applied with a steel trowel to ensure the contact of fresh mortar with the net.
  • Second coat (2 mm) of plaster shall be applied after applying the plaster.
  • A steel trowel is recommended to finish the surface. Sponge float may cause dusting of the surface.
 

CONSUMPTION

4,5 kg/m²

PACKAGING

25 kg polyethylene-reinforced kraft paper bags,

(delivered in pallets or as sling-bags upon request.)

STORING

1 Year Shelf Life*

* If stored in its original package without opening the package under dry, frost free conditions

 

(1 week after opening the package.)

CERTIFICATE OF CONFORMITY

TS 7847/ June 2012 / G3-E5-S3-V2-W3-K2
Ministry of Public Works Pos. No: 04,481

RECOMMENDATION

  • No other materials (lime, cement, gypsum, etc.) shall be added to the prepared mortar.
  • Mortar shall not be used again by mixing with water or dry mortar if its application time has expired.
  • Surface shall be watered in specific intervals within 7 days after the application to ensure the strength of plaster depending on the weather conditions.
  • We recommend that the application shall be performed between +5°C and +35°C.
  • TURUNCU PAKET® REINFORCEMENT PLASTER shall be protected against quick drying under windy weather conditions.
  • It shall not be applied on frozen surfaces.
  • Do not apply under direct sunlight.
  • Do not go beyond the application field and the rules.
  • Do not inhale it directly. Wash your eyes with plenty of water in case of contact with eyes, seek medical attention if required.
  • For detailed information, please request the security data sheet.
  • Contact us for your technical questions and for your questions about all other application conditions.