PRODUCTS

FiNTEK®Cement-Based Thin Finishing Plaster

APPLICATION FIELD

Applied as a thin finishing plaster on traditional and ready-mixed cement-based plaster applications both on interior and exterior surfaces.

REQUIREMENTS

  • Provides a smooth surface for final coating.
  • Provides cost advantage.
  • It can be easily and rapidly applied.

TECHNICAL VALUES

Dry Bulk Density of Hardened Mortar, kg/m³

1600 ± 300

Compressive Strength, N/mm²

≥ 6,0 (CS IV)

Adhesive Strength, N/mm²

≥ 0,2 (FP:B)

Capillary Water Absorption, kg/m² min0.5

W0

Water Vapour Permeability Coefficient, µ

≤ 25

Average Thermal Conductivity, W/m.K (λ10,dry)

≤ 0,93

Reaction to Fire

A1

 

APPLICATION

SURFACE PREPARATION  

  • The surface will always be free of form oil, dust, paint and materials that reduce adherence.
  • Repair of the cracks and holes should be made using appropriate Entegre Repair Mortars before application.
  • Application surface should be dampened with water, if required.

PREPARATION of the MORTAR  

  • FINTEK® should be mixed with ready-mix plaster mixer or by hand (4.5-5,5 lt water/25 kg bag).
  • Application thickness should be between 3 -10 mm for one coat and it will be applied using a plastering trowel.
  • The surface of the plaster will be polished when the plaster becomes hard enough and the surface will be finished with a damp sponge.

CONSUMPTION

Approx. 1.7 kg/m² for 1 mm of thickness

PACKAGING

25 kg Paper Bag,

(delivered in pallets or as sling-bags upon request.)

STORING

1 Year Shelf Life*

* If stored in its original package without opening the package under dry, frost free conditions

 

(1 week after opening the package.)

CERTIFICATE OF CONFORMITY

TS EN 998-1 / February 2017 / A1-GP-CS IV-W1
Ministry of Public Works Pos. No: 04.476/C

RECOMMENDATION

  • No other materials (lime, cement, gypsum, etc.) should be added to the prepared mortar.
  • We recommend the application to be performed between +5°C and +35°C.
  • FINTEK® will be protected against quick drying under windy weather conditions.
  • Surface should be watered in specific intervals within 3 days after the application to ensure its strength.
  • We recommend application of 2 coats to prevent cracking risk due to fast curing when required, particularly for applications performed on summer days.
  • We recommend using fiberglass meshs on the joining areas of different materials and on the points that may be considered to be moving.
  • You should wait at least 10 days for the application be performed on the FINTEK® depending on the ambient temperature.
  • Do not go beyond the application field and the rules.
  • Do not inhale it directly. Wash your eyes with plenty of water in case of contact with eyes, seek medical attention if required.
  • For detailed information, please request the safety data sheet.
  • Contact us for your further inquires and about all other application conditions.