PRODUCTS

SELFFiX®Cement-Based Grout Mortar

APPLICATION FIELD

It is used on cracked and worn concrete surfaces where manual operation is not possible, on broken concretes, for fixing of steel columns to the foundation, for the installation of prefabricated concrete structural elements, for securing all kinds of industrial machinery to the ground and for filling of holes and cavities.

REQUIREMENTS

  • Has high adhesion strength and compressive strength.
  • Does not crack or contract.
  • Resistant against freezing-thawing cycles.
  • May be applied both on interior and exterior surfaces.
  • Provides quick and perfect results.
  • Allows working on areas where manual operation is not possible with its fluidity.
  • Does not segregate or bleed water.
  • Application thickness shall be 10-70 mm.

TECHNICAL VALUES

Class

R4

Mortar Type

PCC

Adhesive Strength, N/mm²

≥ 2

Modulus of Elasticity, GPa

≥ 20

Chloride Content, %

≤ 0,05

Limited Contraction/Expansion, N/mm2

≥ 2

Capillary Water Absorption, kg/m².h0,5

≤ 0,5

Reaction to Fire

A1

 

 

1 DAY

7 DAYS

28 DAYS

Bending Strength, N/mm²

≥ 5

≥ 6

≥ 7

Compressive Strength, N/mm²

≥ 30

≥ 50

≥ 60

 

APPLICATION

SURFACE PREPARATION  

  • The surface of application shall be free of residues that may prevent adhesion. 
  • Moving parts with low adherence shall be moved away from the surface. 
  • Corrosion on metal parts shall be removed and contact with mortar shall be prevented using an anti-corrosion agent. 
  • Absorbent surfaces shall be saturated with water. 
  • Ensure that the mould where the application shall be performed is well cleaned and water-proof, and fix the mould securely. 
  • Water collected on the surface shall be moved away before application.

PREPARATION of the MORTAR  

  • Add powder material to the mixture water put inside a clean mixing vessel (3.5-4,0 lt water/ 25 kg powder), and mix using a hand mixer with low speed at this time.
  • Mix 3-4 minutes more until a homogeneous mixture is achieved after adding all powder.
  • It shall be used in 15-20 as it sets quickly.
  • The mortar prepared shall be applied with an injection pump or by self dissipation depending on the application. 
  • Times specified may differ as per ambient temperature and surface temperature, and the times are reduced at lower temperatures and increased in higher temperatures.

CONSUMPTION

Powder Consumption: 1.9 kg/l

PACKAGING

25 kg Paper Bag,

(delivered in pallets or as sling-bags upon request.)

STORING

6 Months Shelf Life*

* If stored in its original package without opening the package under dry, frost free conditions

 

(1 week after opening the package.)

CERTIFICATE OF CONFORMITY

TS EN 1504-3 / April 2008 Complies with R4 Class. 
Ministry of Public Works Pos. No: 04.613/3C

RECOMMENDATION

  • No other materials (lime, cement, gypsum, etc.) shall be added to the prepared mortar.
  • Plaster shall not be used again by mixing with water or dry plaster if its application time has expired.
  • Ensure that no air is left in the mortar prepared. Otherwise, air bubbles may reduce the adhesive resistance of the product.
  • We recommend that the application shall be performed between +5°C and +35°C.
  • Surface shall be protected against sunlight, wind, rain or frost for the first 24 hours on exterior applications.
  • It shall not be applied on frozen surfaces.
  • Do not apply under direct sunlight.
  • Do not go beyond the application field and the rules.
  • Do not inhale it directly. Wash your eyes with plenty of water in case of contact with eyes, seek medical attention if required.
  • For detailed information, please request the safety data sheet.
  • Contact us for your technical questions and for your questions about all other application conditions.