ELTEK®Cement-Based Hand Plaster

APPLICATION FIELD

Applied on brick, aerated concrete, concrete, fair faced concrete, pumice concrete, briquette walls and ceiling surfaces on both interior and exterior faces of the buildings.

REQUIREMENTS

  • Serves as both the rough plaster and finish plaster as a single product.
  • It can be easily and rapidly applied.
  • Provides a strong surface with high adhesive resistance and strength.

TECHNICAL VALUES

Dry Bulk Density of Hardened Mortar, kg/m³

1600 ± 200

Compressive Strength, N/mm²

≥ 6,0 (CS IV)

Adhesive Strength, N/mm²

≥ 0,3 (FP:B)

Capillary Water Absorption, kg/m² min0.5

W0

Water Vapour Permeability Coefficient, µ

≤ 35

Average Thermal Conductivity (W/m.K) (λ10,dry)

≤0,83

Reaction to Fire

A1

 

APPLICATION

SURFACE PREPARATION  

  • The surface of application will always be free of form oil, dust, paint and materials that reduce adherence.
  • Repair of the cracks and holes should be made with the same material or using appropriate Entegre Repair Mortars before application.
  • Application surface should be dampened with water, if required.
  • Pre-coating will be performed using PRIMEL® for surfaces such as aerated concrete, bricks, etc. 1 day before the application; and using PRIMEL® PLUS for smooth surfaces such as fair faced concrete 1 day before the application.
  • Application is started when the surface is dry.

PREPARATION of the MORTAR  

  • ELTEK® should be mixed with ready-mix plaster mixer or by hand (9-11 l water/50 kg bag).
  • The mortar prepared will be applied with a plastering trowel.
  • It should be applied in 2 coats. 
  • Application thickness should be between 1 cm and 2.5 cm in one coat.
  • If the thickness is more than 2.5 cm, a second coat is applied in max. 2.5 cm thickness after the first coat is set.
  • Surface must be levelled.
  • The surface of the plaster will be polished when the plaster becomes hard enough and the surface will be finished with a damp sponge.

CONSUMPTION

Approx. 15,0 kg/m² for 1 cm of plaster thickness

PACKAGING

25 kg and 50 kg Paper Bag,

(delivered in pallets or as sling-bags upon request.)

STORING

1 Year Shelf Life*

* If stored in its original package without opening the package under dry, frost free conditions

 

(1 week after opening the package.)

CERTIFICATE OF CONFORMITY

TS EN 998-1 / February 2017 / A1-GP-CS IV
Ministry of Public Works Pos. No: 04.476

RECOMMENDATION

  • No other materials (lime, cement, gypsum, etc.) should be added to the prepared plaster.
  • Application should be performed between +5°C and +35°C.
  • ELTEK® will be protected against quick drying under windy weather conditions.
  • Fiberglass meshs should be used on the joining areas of different materials and on the points that may be considered to be moving.
  • Wait at least 10 days for the application to be performed on the ELTEK® depending on the ambient temperature.
  • Surface should be watered in specific intervals within 3 days after the application to ensure its strength.
  • Do not go beyond the application field and the rules.
  • Do not inhale it directly. Wash your eyes with plenty of water in case of contact with eyes, seek medical attention if required.
  • For detailed information, please request the safety data sheet.
  • Contact us for your further inquires and about all other application conditions.