PRODUCTS

SUTOP® B-21Crystallized Capillary Water Insulation Concrete Additive

APPLICATION FIELD

  • It may be safely used for water insulation in drinking water and waste water tanks,
  • On foundations, reinforced concrete curtains,
  • On pre-cast concrete elements,
  • In dams, tunnels,
  • In underground parking lots,
  • In elevator pits,
  • On mass concretes,
  • In water channels,
  • In water treatment facilities,
  • On piled foundations,
  • In swimming pools.

REQUIREMENTS

  • It is an inorganic fluid mixture used for water insulation in concrete.
  • Renders concrete impermeable against very high water pressure (14 bar) from positive and negative sides.
  • During the curing period, it provides forming of smooth, crystalline fibers in the capillary hole. These fibers reduce hole in concrete and prevent water from passing through the concrete mixture.
  • After curing, it closes cracks up to 0.4 mm with its crystallization effect.
  • Reduces cost in terms of labour and time.
  • It is easy to use.
  • It does not clump during mixing as it is in liquid state.
  • It does not prevent breathing of the concrete.
  • It does not harm the environment.
  • Approved for drinking water.
  • It is continuously active and becomes a permanent part of concrete.
  • Protects the reinforcement against corrosion. It is compatible with all kinds of plasticizers and water reducing additives.
  • It is the best solution for bored piled raft foundation.
  • It has no side effect on hardening and curing properties of concrete.
  • Improves the strength and freezing-thawing resistance of concrete. It has been observed that it improves the strength of concrete by 3% in all tests performed.
  • There is no need for protection as it cannot be damaged.
  • It provides definite and continuous water insulation without requiring any other type of water insulation in concretes.

TECHNICAL VALUES

Colour

Clear Brown

Formation

Fluid

Density

1,17 g/cm3

pH

11,2

Application Temperature

+5 ºC / +30 ºC

 

APPLICATION

PREPARATION of the MORTAR  

  • Ensure that the mixture ratio of cement and water for the concrete that shall be added with SUTOP® B-21 is less than 0.55.
  • Thoroughly mix SUTOP® B-21 before using.
  • Application time is approximately 45 minutes after being added to concrete.
  • When type II and III type of Portland cement is used, it is advisable to use setting retarder.
  • Conformity tests shall be performed before use.
  • Crystallization may occur if SUTOP® B-21 is stored below +8 ºC. The material can be re-used after mixing and homogenizing.

CONSUMPTION

For concretes to be insulated using SUTOP® B-21
With a ratio of 2% of the cement amount if Water/cement ratio (w/c) ≤ 0.45
With a ratio of 2.5% of the cement amount if 0.45 < Water/cement ratio (w/c) ≤ 0.50
With a ratio of 3% of the cement amount if 0.50 < Water/cement ratio (w/c) ≤ 0.55
For concretes with Water/cement ratio (w/c) ≥ 0.55; water insulation with SUTOP® B-21 is not suitable. 
Dosing at concrete plant: 
SUTOP® B-21 may be added to the mixture with the mixture water as the final component. 
Dosing at construction site: 
SUTOP® B-21 is added to the mixer at a ratio of 2-3% and mixed for 3-5 minutes. Mixing shall be performed without delay.

PACKAGING

30 kg drums

STORING

1 Year Shelf Life*

* If stored in its original package without opening the package under dry, frost free conditions

 

(1 week after opening the package.)

CERTIFICATE OF CONFORMITY

RECOMMENDATION

  • Foaming may occur on concretes applied with SUTOP® B-21 due to the mixture.
  • It does not have any corrosive effect and does not damage the reinforcement.
  • Where required, conformity tests shall be carried out when other additives shall be added to the concrete.
  • Conformity tests shall be performed according to specific standards before the application.
  • Necessary precautions shall be taken in the vicinity to prevent contamination.
  • Sieve sizes of aggregates shall be uniform.
  • SUTOP® B-21 reinforced concrete shall be produced, cast and placed according to the relevant norms.
  • It rarely affects the settling of concrete.
  • Storage conditions shall be considered while it is transported.
  • Work clothing, protective gloves and goggles conforming with the Occupational Health and Safety Rules shall be used during the application.
  • Do not inhale it directly.
  • Avoid contact with eye and skin.
  • Consult a physician immediately in case of swallowing.
  • Food and drinks shall not be allowed in application areas.
  • Shall be stored away from the children.
  • Do not go beyond the application field and the rules.
  • For detailed information, please request the security data sheet.
  • Contact us for your technical questions and for your questions about all other application conditions.