PRODUCTS

ŞAPSER® RAPIDCement-Based Easy To Use Rapid Hardening Screed

APPLICATION FIELD

Used for achieving smooth surfaces in interior and exterior areas where rapid reaction is required.

REQUIREMENTS

  • Ready to use.
  • Saves time and labour.
  • It becomes ready for pedestrian traffic within 6 hours.
  • You may apply the final coating within 24 hours.

TECHNICAL VALUES

Bending Strength, N/mm²

≥ 3

Compressive Strength, N/mm² (1 day)

≥ 4

Compressive Strength, N/mm² (28 days)

≥ 7

Adhesive Strength, N/mm²

≥ 1

 

APPLICATION

SURFACE PREPARATION  

  • The application surface shall be solid, clean and dry.
  • The surface shall be free of oil, dust, paint and materials that reduce adherence.
  • Repairs required on old floors shall be made using appropriate Entegre Repair Mortars.

PREPARATION of the MORTAR  

  • Mortar prepared by mixing with a hand mixer at proper speed within 2-3 minutes (3-3.5 l of water/25 kg bag) shall be spread on the surface, compacted and levelled with a thickness of 3-10 cm.
  • Prepare mortar with the amount suitable for application considering that the mortar prepared shall start to harden within 10 minutes.
  • When the surface is hardened, it shall be corrected with a mechanical finishing tool.

CONSUMPTION

18 kg/m² for 1 cm of thickness

PACKAGING

25 kg Paper Bag,

(delivered in pallets or as sling-bags upon request.)

STORING

1 Year Shelf Life*

* If stored in its original package without opening the package under dry, frost free conditions

 

(1 week after opening the package.)

CERTIFICATE OF CONFORMITY

TS EN 13813 / December 2004 / CT-C7-F3

RECOMMENDATION

  • No other materials (lime, cement, gypsum, etc.) shall be added to the prepared mortar.
  • Mortar shall not be used again by mixing with water or dry mortar if its application time has expired.
  • We recommend that the application shall be performed between +5°C and +35°C.
  • We recommend you to use expansion joints with proper intervals for applications on very wide areas.
  • (On areas greater than 25 m²)
  • It shall not be applied on frozen surfaces.
  • Do not apply under direct sunlight.
  • Do not go beyond the application field and the rules.
  • Do not inhale it directly. Wash your eyes with plenty of water in case of contact with eyes, seek medical attention if required.
  • For detailed information, please request the security data sheet.
  • Contact us for your technical questions and for your questions about all other application conditions.